Creep Rupture Test of GFRP Bolt

High anti-corrosion quality of GFRP (Glass Fiber Reinforced Polymer) solid bolt was born for permanent
Home - SupNews - Creep Rupture Test of GFRP Bolt
Creep Rupture Test of GFRP Bolt
SupNews
2022-10-19
7889

High anti-corrosion quality of GFRP (Glass Fiber Reinforced Polymer) solid bolt was born for permanent supporting solutions (100+ years of service life), which has extreme high demand for corrosion resistance and creep rupture strength, as it is related to performance in long term loading.

The success and reliability of the production fully depends on the comprehensive capacity of the manufacturer, such as raw material selection, production equipment, process, technique, quality control, etc. 
 
SupFRP has achieved great success on production of this high-tech GFRP bolt and the products have been widely installed in various projects globally. 
 
SupFRP has completed the Anti-Corrosion Test successfully in 2018, and after that, SupFRP conducted the Creep Rupture Test. Starting from 2020, the whole duration took one year long by independent test laboratory. We are proud to announce the test result was extraordinary. 
 
Tested by:
NSERC Research Chair in Innovative FRP Reinforcement for Concrete Infrastructure
Canada Research Chair in Advanced Composite Materials for Civil Structures
Department of Civil Engineering
University of Sherbrooke
 
Test specimens: SupFRP GFRP Solid Bolt S25 (25 mm diameter)
 
Test method: according to test standard ASTM D7337
 
Test results:
The creep rupture strength at one million hours of this GFRP Solid Bolt S25 is above 60% of the average UTS. This result is far more than 35% in Canadian standard CSA S807.
 


Recommended values for design using GFRP solid bolts S25 (Based on ACI 440.IR-15)
 
·Guaranteed tensile strength: Average UTS – 3 times standard deviation = 1291 MPa – (28.8 MPa × 3) = 1204 MPa (421 kN)
·Design tensile strength = Guaranteed tensile strength × Environmental reduction factor = 1204 MPa × 0.7 = 843 MPa (295 kN)
·Creep rupture strength: (60% of the average UTS)/Safety factor = (60% × 1291 MPa)/1.67 = 464 MPa (162 kN) (around 55% of design tensile strength)

Recommend
SupAnchor Launches High-Performance GFRP Dowel Bar for Durable Concrete Pavements

SupAnchor introduces a corrosion-free GFRP dowel bar with 100-year service life, high strength, and superior load transfer, ideal for jointed pavements and EMI-sensitive areas.

Self-Drilling Anchor System Accelerates Critical Metro Tunneling in Challenging Ground

SupAnchor’s self drilling anchor system proves vital in a European metro expansion, overcoming fractured rock and groundwater to ensure safe, rapid tunneling and slope stabilization.

SupAnchor® Introduces Stainless Steel Self-Drilling Hollow Anchor for Corrosive Environments

SupAnchor's new stainless steel self-drilling hollow anchor combats corrosion in marine, chemical, and humid projects. The R32SS/15 model delivers 405 kN ultimate load, long service life, and compatibility with standard accessories.

SupAnchor's Self Drilling Anchor System Excels in Challenging Infrastructure Project

A major European tunnel project overcomes fractured rock and high groundwater using SupAnchor's self drilling anchor bolts, showcasing advanced ground stabilization and rapid installation.

SupAnchor Launches Innovative GFRP Hollow Injection Bolts for Global Geotechnical Reinforcement

SupAnchor unveils its new SupFRP GFRP Hollow Injection Bolts, integrating high tensile strength, corrosion resistance, and full grouting capability for slope stabilization, tunneling, and soft rock support.

Tongzhou Bay, Binhai New Village, Sanyu District, Nantong City, Jiangsu 226300, China
No.13 Jin Teng Road, Economy Zone, Dujiangyan Sichuan 611833, China